EV.8.4.1 The AMS must measure the cell voltage of every cell
When single cells are directly connected in parallel, only one voltage measurement is needed
EV.8.4.3 All voltage sense wires to the AMS must meet one of:
a. Have Overcurrent Protection EV.8.4.4 below
b. Meet requirements for no Overcurrent Protection listed in EV.8.4.5 below
EV.8.4.4 When used, Overcurrent Protection for the AMS voltage sense wires must meet the following.
a. The Overcurrent Protection must occur in the conductor, wire or PCB trace which is directly connected to the cell tab.
b. The voltage rating of the Overcurrent Protection must be equal to or greater than the smaller of:
The sum of the cell voltages sensed by the AMS board
The sum of the cell voltages sensed between galvanic isolation boundaries on the cell board/AMS
AMS is a distributed AMS system (one cell measurement per board)
Sense wire length is < 25 mm
AMS board has Overcurrent Protection