EV.8.1.1 The Shutdown Circuit consists of the following components, connected in series:
a. Accumulator Management System (AMS) EV.8.3
b. Insulation Monitoring Device (IMD) EV.8.6
c. Brake System Plausibility Device (BSPD) EV.8.7
e. Interlocks (as required) EV.8.9
f. Master Switches (GLVMS, TSMS) EV.8.10
h. Brake Over Travel Switch (BOTS) T.3.2
EV.8.1.2 The Shutdown Circuit must directly carry the current driving the Accumulator Isolation Relays (AIRs) and the Precharge Circuit Relay.
EV.8.1.3 The AMS, IMD, and BSPD parts of the Shutdown Circuit must be designed as Normally Open contacts
EV.8.1.4 The AMS, IMD and BSPD must have completely independent circuits to Open the Shutdown Circuit.
The respective circuits must be designed such that a failure cannot result in electrical power being fed back into the Shutdown Circuit.
EV.8.1.5 The Shutdown Buttons, BOTS, TSMS, GLVMS and Interlocks must directly carry the Shutdown Circuit current
Shutdown Bu ons
Shutdown Bu ons
Shutdown Bu ons
GLV System
GLV System
GLV System
Brake
System Plausibility Device
Brake
System Plausibility Device
Brake
System Plausibility Device
Insula on
Monitoring Device
Insula on
Monitoring Device
Insula on
Monitoring Device
Iner a
Switch
Iner a
Switch
Iner a
Switch
cockpit
cockpit
cockpit
le
le
le
right
right
right
LV
LV
LV
Accumulator
Accumulator
Accumulator
Brake
Brake
Brake
Management Over TS HVD Interlock(s)
Management Over TS HVD Interlock(s)
Management Over TS HVD Interlock(s)
System
System
System
Travel
Switch
Travel
Switch
Travel
Switch
Interlock
Interlock
Interlock
Trac ve System
GLV Fuse Master Switch
Trac ve System
GLV Fuse Master Switch
Trac ve System
GLV Fuse Master Switch
GLV
Ba ery
GLV
Ba ery
GLV
Ba ery
Accumulator Container(s)
Accumulator Container(s)
Accumulator Container(s)
Precharge
Precharge
Precharge
GLV System
GLV System
GLV System
Chassis
Chassis
Chassis
TSMP
TSMP
TSMP
TSMP
TSMP
TSMP
GLVMP
GLVMP
GLVMP
G D
G D
G D
HV
HV
HV
HV+
HV+
HV+
AIR AIR
AIR AIR
AIR AIR
Accumulator
Fuse(s)
Accumulator
Fuse(s)
Accumulator
Fuse(s)
Trac ve
System
Trac ve
System
Trac ve
System
Trac ve
System
Trac ve
System
Trac ve
System
Precharge
Precharge
Precharge
Control
Control
Control
GLV System Master Switch
GLV System Master Switch
GLV System Master Switch
EV.8.1.6 The team must be able to demonstrate all features and functions of the Shutdown Circuit and components at Electrical Technical Inspection.