< Previous | Contents | Next >

EV.10.4 Charging Shutdown Circuit Operation

EV.10.4.1 When Charging, the AMS and IMD must:

a. Monitor the Accumulator

b. Open the Charging Shutdown Circuit if a fault is detected. EV.10.4.2 If the Charging Shutdown Circuit is Opened:

a. All current flow to the Accumulator must stop immediately

b. The voltage in the Tractive System must be Low Voltage EV.1.2 in five seconds or less

c. The Charger must be turned off

d. The Charger must remain disabled until manually reset