< Previous | Contents | Next >

EV.6.7 Voltage Indicator

Each Accumulator Container must have a prominent indicator when High Voltage EV.1.1 is present at the vehicle side of the AIRs

EV.6.7.1 The Voltage Indicator must always function, including when the Accumulator Container is disconnected or removed

EV.6.7.2 The voltage being present at the connectors must directly control the Voltage Indicator using hard wired electronics with no software control.

EV.6.7.3 The control signal which closes the AIRs must not control the Voltage Indicator EV.6.7.4 The Voltage Indicator must:

a. Be located where it is clearly visible when connecting/disconnecting the Accumulator Tractive System connections

b. Be labeled “High Voltage Present”