< Previous | Contents | Next >
All parts belonging to the Tractive System must meet F.11 EV.5.9 Housings and Enclosures
EV.5.9.1 Every housing or enclosure containing parts of the Tractive System other than Motor
housings, must be labeled with the:
a. Symbol specified in ISO 7010-W012 (triangle with black lightning bolt on yellow background)
b. Text “High Voltage” if the voltage meets EV.1.1
EV.5.9.2 If the housing material is electrically conductive or possibly electrically conductive, it must have a low resistance connection to GLV System Ground, see EV.7.7